What's new

What has changed, newest first. Each one links to its place in the guide.

  • A clearer scenario library

    Tap a scenario to read its story, aims and steps before you run it. Pick a source and an age group to narrow the list. On a phone the library opens full screen.

    Where: The Scenario tab on the controller.

    In the guide →
  • NAP teaching cases

    Ready-made adult and paediatric cases now come with every library, from VF and PEA to bronchiolitis and DKA. Duplicate one to make your own copy.

    Where: Under NAP in the scenario library.

    In the guide →

  • Debrief has its own tab

    Switch recording on, open the live run and find past recordings in one place. Don't forget to start the clock with ▶. Audience has moved to Advanced.

    Where: The Debrief tab on the controller.

    In the guide →
  • Trends full screen

    Double-tap a trend, or tap its expand button, to see it full screen. Pinch or drag to move through time, and tap a moment to see the values and events at that point.

    Where: The trend on the debrief page, and Trends on the monitor.

    In the guide →

  • Oesophageal tube during CPR

    Pick Oesophageal after bagging during CPR and the capnogram shows a few shrinking humps under the compressions, then goes flat. That early trace is the one that misleads.

    Where: Hold the EtCO₂ tile, Capnogram shape, during CPR with RR set for bagging.

    In the guide →
  • Small visual updates on the controller

    Switch good or poor CPR with a long press on the CPR button and a "CPR 👍" or "CPR 👎" tag now shows beside it. Tile notes are tidier too: one short note on top, longer explanations on a line under the pair, so the − / + stay put.

    Where: The CPR button during CPR, and the Patient tab.

    In the guide →

  • Free ECG and blood gas generators

    Make a printable 12-lead ECG at true scale, or an ABG or VBG result slip, without starting a session. Save it as a picture or PDF for handouts and quizzes.

    Where: Tools, in the bar at the top and in the footer.

    In the guide →

  • Drifts: vitals that change on their own

    A vital moves to your target by itself over 1 to 15 minutes. Drift several together, pick the shape of the change, or start from a built-in set such as Bleeding or Sepsis.

    Where: Advanced → Drifts on the controller. Built-in sets are for adult patients.

    In the guide →

  • Breathing and capnography on the RR and EtCO₂ tiles

    Hold the RR tile to set the breathing pattern, or EtCO₂ for the capnogram shape. The tile shows a tag when either isn't normal.

    Where: Hold the RR or EtCO₂ tile on the Patient tab.

    In the guide →
  • Controls laid out for tablets and computers

    On a landscape tablet or a computer, the vitals stay on screen beside the presets, and the other tabs open alongside them. ⇄ swaps the sides for left- or right-handed use.

    Where: Automatic when the screen is held in landscape. ⇄ and Fullscreen are at the top.

    In the guide →

  • Posterior and right-sided leads

    Learners can record V7–V9 or V3R–V6R on the 12-lead, to look for a posterior or right ventricular infarct.

    Where: Chest leads, at the top of the monitor's 12-lead screen.

    In the guide →
  • T-wave inversion and a clearer ECG tab

    Add ischaemic T-wave inversion (anterior, inferior or lateral) and ST depression, alone or together, to build an NSTEMI. A line at the top of the 12-lead section now shows what is on it, with Reset beside it.

    Where: The new Ischaemia section on the ECG tab.

    In the guide →
  • Blood gases saved with a scenario

    Keep up to five blood gases with a scenario. When you run it, they're waiting at the top of the blood gas panel, ready to release.

    Where: With the scenario open in the builder, set up a gas in Advanced → Blood gas and tap Add to scenario.

    In the guide →

  • Fewer interruptions

    Most NAP updates no longer end your session. If the screens pause for a moment, they come back on their own.

    Where: There is nothing you need to do.

    In the guide →
  • Clearer traces on big screens

    Traces now keep the same thickness on any screen, so a projector or large display is as easy to read as a laptop. Tablets and larger screens start with Bold.

    Where: Traces, in the monitor's settings. You can still pick Normal, Bold or Heavy, and each screen remembers your choice.

    In the guide →

  • Share a patient as a link

    Copy any preset, or the patient you've just built, as a link. Opening it starts a session with that patient, or hands it to a controller you already have open.

    Where: Copy link in the presets list on the Patient tab, or hold any preset.

    In the guide →

  • See what every combination does

    Pick a patient and rhythm to see the therapy outcomes NAP offers.

    Where: The rhythm explorer, in the guide.

    In the guide →
  • The WPW pattern

    A short PR and a delta wave on a wide QRS. Pair it with AF for pre-excited AF: fast, broad and irregular, and adenosine can speed it up or tip it into VF.

    Where: Conduction on the ECG tab; adenosine on the Therapy tab.

    In the guide →
  • Brugada type 1

    A coved ST in V1 and V2 running into a negative T, the classic STEMI mimic. It shows on the 12-lead.

    Where: Metabolic & mimics on the ECG tab.

    In the guide →

  • Scenarios are easier to find and build

    Packs are labelled and stay chosen when you switch tabs, a Running line leads back to the scenario in progress, and Capture now comes first when you build.

    Where: The Scenario tab on the controller.

    In the guide →

  • All monitoring on or off

    Attach or detach every patient probe in one tap. A new patient now starts with all of them attached.

    Where: The two screen buttons beside the Vitals heading, on the Patient tab.

    In the guide →
  • Presets take less room

    Three presets of your choice sit on the Patient tab; every other preset, and the ones you saved, are one tap away. Pin the three you want, separately for adult and paediatric patients.

    Where: The grid button beside the pinned presets, on the Patient tab.

    In the guide →

  • Adenosine follows the rhythm

    Results match the rhythm: SVT converts; flutter, atrial tachycardia and fast AF briefly slow to reveal themselves. Atrial tachycardia is now in the rhythm picker.

    Where: Give adenosine… on the Therapy tab; atrial tach is on the ECG tab, after SVT.

    In the guide →

  • Choose therapy results together

    Co-instructors can choose shock and adenosine results; the lead’s choice takes priority.

    Where: The result sheets on every instructor’s controller.

    In the guide →
  • A closer look at the blood gas

    Open a released blood gas to read the whole card fitted to the window.

    Where: Double-tap the result card, or tap the expand icon in its upper-right corner. On the monitor and on viewers.

    In the guide →
  • Set EtCO₂ during CPR

    Choose an EtCO₂ value for the arrest and keep it when CPR stops and restarts.

    Where: The toggle appears in the EtCO₂ tile on the controller’s Patient tab while CPR is running.

    In the guide →

  • A closer look at the 12-lead

    Open a captured 12-lead to fill the screen, then pinch to zoom in and read it.

    Where: Double-tap a captured 12-lead, or tap Full view. On the monitor and on viewers.

    In the guide →

  • Coarse or fine VF

    VF looks more like the real thing, and it can now be fine: small and easy to mistake for asystole.

    Where: Pick VF in the ECG tab, then Coarse or Fine.

    In the guide →
  • Pulse button

    A small heart shows whether the patient has a pulse. One tap takes it away or gives it back.

    Where: On the controller, next to the CPR button.

    In the guide →

  • Trends

    See the last 15 minutes to an hour at a glance: heart rate, SpO₂, blood pressure, CO₂ and more.

    Where: Tap Trends on the monitor.

    In the guide →
  • Pause the scenario

    Freeze every screen to talk something through, then carry on exactly where you stopped.

    Where: The button is next to Adult/Paediatric.

    In the guide →
  • The trend in your debrief

    Recorded sessions now show what the monitor displayed, so you can point at the moment things changed.

    Where: It sits above the timeline.

    In the guide →
  • Full screen

    One tap hides the browser bars on laptops, Android and iPad.

    Where: The button is next to the session code on the monitor.

    In the guide →

← Back to NAP

Rotate your device to portrait

NAP is built for portrait. Turn your phone upright to continue.